| BIAR reactor sampling systems - ACTIFLOW |
|
Technical caracteristics Nominal pressure : -1 à 16 [bar] Nominal temperature : - 20 à 200 [ºC] Standard outlet diameter : 10 [mm] Raised volume / lift : 100 [ml] Volume delivery : 400 [ml/min] Viscosity : 2000 [mPa/sec] |
Materials Standard stainless steel 1.4435 or 316L. All parts in contact with the product are supplied in accordance with the customers choice. (Tantalum); Titane; Hastelloy® ; etc. |
 WHAT'S NEW? Its principle of function is to push the liquid by a piston and chamber to the outside of the reactor. As a result of gravity, the liquid flows via a loop back into the reactor. In accordance with the requirements a sampler and / or an analytical apparatus for the measurement of certain values (i.e. pH, viscosity, Redox, Conductivity, etc.) can be installed in this circuit. |
Advantages The liquid is never sucked but pushed up. No aspiration problems. Avoids the use of a vacuum pump. Guaranteed sampling even under extreme vacuum conditions 10--7 [mmHg] Magnetic drive in a two chamber system avoids the physical contact as well as dynamic seals. Small piston lift. Compact design. Simple operation. Self-cleansing. Closed sampling system. Excellent draining. |
 |
|
|